1. Thermostatic Cartridge Technical Data: Recommended Pressure:0.1-0.5Mpa Inlet Cold Water Temperature:8-29 degree centigrade Inlet Hot Water Temperature:55-85 degree centigrade Outlet Water Temperature Range:20 degree centigrade-50 degree centigrade Safety Stop:38 degree centigrade
2. Cold Water Supply Failure Test: Within 5 seconds of cold water supply failure, outflow rate less than 200ml (if the outflow rate more than 200ml, outlet temperature less than 42 degree centigrade).Then within 30 seconds, the outflow rate more than 300ml
3. Outflow Temperature Auto-aligning Sensitivity: When inlet water temperature is constant and pressure varies by 20%, outlet water temperature change will be equal or less than 2 degree centigrade. When inlet water pressure is constant and hot water temperature varies from 55 degree centigrade to 85 degree centigrade and cold water from 8 degree centigrade to 29 degree centigrade, outlet water temperature change will be equal or less than 2 degree centigrade. |
|
|
|
|
|
|
|
|
|
|
|