Yng Horng Trading Co., Ltd. |
|
|
|
|
|
|
|
|
Description: Order No.* 178-953-2 178-954-2 178-952-2 178-955-2 Type mm inch/mm mm inch/mm Measuring range Z-axis : 350m (12000in) X-axis : 12.5mm (.5") Drive Unit
Drive speed Measuring:0.25mm/s (.01"/s),(.02"/s), Returning: 1mm/s (.04"/s) Connecting cable length 1m (39") Mass 190g (.42 lbs.) Detector Provided Detecting method 178-390 178-395 Differential inductance Measuring range 350m (-200m to +150m)/13780in (-7880in to +5900in) Material of stylus Diamond Stylus tip radius 5m(200in) 2m (80in) Radius of skid curvature 40mm (1.57") Measuring force 4mN (0.4gf) 0.75mN(0.075gf) Mass 18g (.04 lbs) Display Unit Assessed profile Primary profile (R), Roughness profile (R), DIN4776, MOTIF.R, MOTIF.W Evaluation parameter Ra, Ry, Rz, Rp, Rq, Rv, Sm, S, Pc, R3z, mr, Rpk, Rvk, c,Rk, Mr1, Mr2, Lo, Ppi, R, AR, Rx, A1, A1, Vo, HSC, mrd,sk, Ku, a, q, Wte, Wt, W, AW. Analysis graph BAC1, BAC2, ADC Roughness standard JIS, DIN, ISO, ANSI Sampling length(L) 0.08mm, 0.25mm, 0.8mm, 2.5mm, 8mm (0.003", .01", .03", .1", .3" Cut-off length c: 0.08mm, 0.25mm, 0.8mm, 2.5mm, 8mm (0.003"), .1", .03",.1",.3") s:2.5m, 8m, 25m(.100in, 320in, 1000in) Number of sampling spans x1, x3, x5, xl** Digital filter 2CR, PC75 (phase corrected), Guass Resolution/range 0.4m/350m (16.4in/13780in), 0.1m/100m (4.1in/4000in), 0.05m/50m (2.0in/2000in), 0.01m/10m (0.5in/400in). Display range Ra, Rq: 0.01m-100m(.4in-4000in) Ry, Rz, Rt, Rv, R3z, Rk, Rvk, R, Rx, W, Wx, Wte: 0.02m-350m (.8in-14000in) Aw. AR : 2.0-350m (80-1400in) S, Sm: 2m-4000m (79in-160000in) PC: 2.5/cm-5000/cm (6.35/inch-12700/inch) c:-350m-350m(-14000-14000Min) Lo:0.1mm-99.999mm(.004inch-9.999inch) mr, Mr1, Mr2, mrd: 0-100% A1, A2:0-15000 a, q, Ku: 0.01-100 Vo:0.0000-999.99 Recording magnification Vertical: 10x, 20x, 50x, 100x, 200x, 500x, 1000x, 2000x, 5000x, 10000x, 20000x, 50000x, 100000x, AUTO Horizontal: 1x, 2x, 5x, 10x, 20x, 50x, 100x, 200x, 500x, 1000x, AUTO Printer Thermal printer (printing width: 48mm (1.89")) Statistical processing Maximum value, Minimum value, Mean vale, (for each parameter) Standard deviation(), Pass ratio, Frequency distribution table. Tolerance judgment Upper and lower limit values for three parameters can be specified. Measuring condition 5 sets of measuring conditions storage. Auto-sleep (turning off) After five minutes without operation Calibration Automatic calibration entering the value of roughness specimen Power supply Via AC adapter (DC7, 5V, 1.5W)/built-in rechargeable battery Rechargeable battery Charging time: 15hours (for 1000 measurements without printing) Data output RS-232C input/output, SPC output Mass Approximately 1200g (2.64 lbs) |
|
|
|
|
|
|
|
|
|
|
|